Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 130

Advertising
background image

130

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

Chapter 3

Programming and Parameters

MO

TOR C

ONTROL

Fie

ld Co

nf

ig

91

[Fld Reg Kp]
Proportional gain (K

P

) of the flux regulator expressed as a percentage of Par

97 [Fld Reg Kp Base]. Leave set to the default value for permanent magnet
motor applications.

Default:

Min/Max:
Units:

2.00

0.00 / 100.00
%

Real

97

92

[Fld Reg Ki]
Integral gain (K

I

) of the flux regulator expressed as a percentage of Par 98 [Fld

Reg Ki Base]. Leave set to the default value for permanent magnet motor
applications.

Default:

Min/Max:
Units:

1.00

0.00 / 100.00
%

Real

98

97

[Fld Reg Kp Base]
The proportional gain (K

P0

) of the field current regulator (base value). Leave

set to the default value for permanent magnet motor applications.

Default:

Min/Max:

3276.70

0.10 / 32767.00

Real

91

98

[Fld Reg Ki Base]
Integral gain (K

I0

) of the field current regulator in (base value). Leave set to

the default value for permanent magnet motor applications.

Default:

Min/Max:

3276.70

0.10 / 32767.00

Real

92

456

[Fld Weaken Ratio]
The ratio of Motor Nameplate Base Speed to Par 45 [Max Ref Speed] when
Par 469 [Field Mode Sel] = 1 “Field Weaken”. This value is the percentage of
the maximum application speed when field weakening will begin: “Motor
Base Speed” / Par 45 [Max Ref Speed] x 100. If Par 469 [Field Mode Sel] = 0
“Base Speed”, this parameter must be = 100%. Leave set to the default value
for permanent magnet motor applications.

Default:

Min/Max:
Units:

100

0 / 100
%

16-bit
Int

921,
469

462

[Flux Divide]
Selects division by flux for Inertia Compensation or Torque Reference. Leave
set to the default value for permanent magnet motor applications.
Note: Added for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =

“Torque Ref”

“Torque Ref”
“Inertia Comp”

16-bit
Int

463

[Flux Filter BW]
Adjustable low pass filter on the value of Par 500 [Flux Ref Pct]. The filtered
result is used by the Torque Reference divide by flux function. Leave set to the
default value for permanent magnet motor applications.
Note: Added for firmware version 3.001.

Default:

Min/Max:
Units:

50

0 / 2000
ms

16-bit
Int

467

[Max Fld Flux Pct]
Maximum allowable field flux. The maximum value (100%) corresponds to
the value set in Par 280 [Nom Mtr Fld Amps]. The value of this field linearly
affects the field current, unless a flux curve is set in Pars 916, 917, and 918
[Fld Const xx Pct]. Leave set to the default value for permanent magnet
motor applications.
Note: This parameter can be assigned to an analog input or output.

Default:

Min/Max:
Units:

100

Par 468 [Min Fld Curr Pct] / 100
%

16-bit
Int

468

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

A

A

A

ATTENTION: Failure to set this parameter to a value appropriate for the intended application could result in excessive
motor speed, equipment damage, and/or bodily injury.