Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

189

Programming and Parameters

Chapter 3

CO

M

M

UNIC

AT

IO

NS

Masks

&

O

w

ne

rs 631

[Decel Mask]
Controls which adapters can select the deceleration ramp rate (Pars 662
[Decel Time 1] and 32 [Decel Time 2]) of the drive.

See [Logic Mask]

32,
662

Da

ta

Li

n

ks

610
611

[Data In A1] – Link A Word 1
[Data In A2] – Link A Word 2
Parameter number whose value will be written from a communications
device data table. The number will not be updated until the drive is
stopped.
See your communications option manual for datalink information.

Default:

Min/Max:

0 (0 = “Disabled”)

0 / 1410

16-bit
Int

612
613

[Data In B1] – Link B Word 1
[Data In B2] – Link B Word 2

See [Data In A1] – Link A Word 1.

16-bit
Int

614
615

[Data In C1] – Link C Word 1
[Data In C2] – Link C Word 2

See [Data In A1] – Link A Word 1.

16-bit
Int

616
617

[Data In D1] – Link D Word 1
[Data In D2] – Link D Word 2

See [Data In A1] – Link A Word 1.

16-bit
Int

618
619

[Data Out A1] – Link A Word 1
[Data Out A2] – Link A Word 2
Parameter number whose value will be written to a communications device
data table.

Default:

Min/Max:

0 (0 = “Disabled”)

0 / 1410

16-bit
Int

620
621

[Data Out B1] – Link B Word 1
[Data Out B2] – Link B Word 2

See [Data Out A1] – Link A Word 1.

16-bit
Int

622
623

[Data Out C1] – Link C Word 1
[Data Out C2] – Link C Word 2

See [Data Out A1] – Link A Word 1.

16-bit
Int

624
625

[Data Out D1] – Link D Word 1
[Data Out D2] – Link D Word 2

See [Data Out A1] – Link A Word 1.

16-bit
Int

1319 [Data In Val Sel]

Selects the Datalink parameter register to display in Par 1320 [Data In Sel
Data].

Default:

Min/Max:

610

610 / 617

16-bit
Int

1320

1320 [Data In SelData]

Displays the value selected in Par 1319 [Data In Val Sel].

Default:

Min/Max:

Read Only

0 / 2

31

32-bit
Int

1319

Se

cu

ri

ty

591

[Logic Mask]
Determines which ports can control the drive. If the bit for a port is set to “0,” the port will have no control functions except for stop. 0 = Control Masked, 1
= Control Permitted, x = Reserved.

1376 [Logic Mask Act]

Indicates the status of the logic mask for the DPI ports. When bit 15 is set, network security is
controlling the logic mask instead of Par 591 [Logic Mask]. 0 = Control Masked, 1 = Control
Permitted, x = Reserved.

Read Only

591

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

Options

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

DP

I P

or

t 5

DP

I P

or

t 4

DP

I P

or

t 3

DP

I P

or

t 2

DP

I P

or

t 1

D

igital In

Default

x

x

x

x

x

x

x

x

x

x

1

1

1

1

1

1

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

A

Options

Se

cur

ity

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

DP

I P

or

t 5

DP

I P

or

t 4

DP

I P

or

t 3

DP

I P

or

t 2

DP

I P

or

t 1

Digital In

Default

0

x

x

x

x

x

x

x

x

x

1

1

1

1

1

1

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0