Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 168

Advertising
background image

168

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

Chapter 3

Programming and Parameters

APPLIC

AT

IONS

Win

der

Fu

nc

ti

on

s

1284 [Ref Spd Source]

Parameter number from which the line speed reference (used for inertia
compensation and line speed reference) will be read.
Notes: Added options 0…47 for firmware version 4.001. Added option 48
“Resolver Spd” for firmware version 5.002.

Default:

0 =

“Not Used”

16-bit
Int

Options:

1285 [Ref Speed Gain]

Gain value for the line speed reference. The value of this parameter depends on the
value of Par 1284 [Ref Spd Source]. The value of [Ref Speed Gain] is used to obtain
a line speed reference = 100% at its maximum value.

Default:

Min/Max:

0

0 / 32767

16-bit
Int

1284

1286 [Ref Line Speed]

Line speed percentage.

Default:

Min/Max:
Units:

Read Only

0.00 / 150.00
%

Real

1287 [Static F Zero]

Enables/Disables friction compensation.
“Enabled” = The fiction compensation value is added to all speed values.
“Disabled” = The static friction compensation value is added to Par 1286 [Ref

Line Speed] = 1.5%.

Default:

Options:

0 =

0 =
1 =

“Disabled”

“Disabled”
“Enabled”

16-bit
Int

1286

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

0 =

“Not Used”

17 = “Max Fld Pct” (Par 467)

34 = “UsrDefined15” (Par 518)

1 =

“Cur Lim Pos” (Par 8)

18 = “Fld Ref Pct” (Par 500)

35 = “Load Comp” (Par 698)

2 =

“Cur Lim Neg” (Par 9)

19 = “UsrDefined0” (Par 503)

36 = “Out Volt Lvl” (Par 921)

3 =

“CurLimPosOut” (Par 10)

20 = “UsrDefined1” (Par 504)

37 = “Filt Trq Cur” (Par 928)

4 =

“CurLimNegOut” (Par 11)

21 = “UsrDefined2” (Par 505)

38 = “Speed Ratio” (Par 1017)

5 =

“TrqRedCurLim” (Par 13)

22 = “UsrDefined3” (Par 506)

39 = “Spd Draw Out” (Par 1018)

6 =

“Torque Ref” (Par 39)

23 = “UsrDefined4” (Par 507)

40 = “Roll Diam” (Par 1154)

7 =

“Trim Torque” (Par 40)

24 = “UsrDefined5” (Par 508)

41 = “Tension Red” (Par 1179)

8 =

“TorqueReg In” (Par 41)

25 = “UsrDefined6” (Par 509)

42 = “Torq Cur Pct” (Par 1193)

9 =

“Trim Ramp” (Par 42)

26 = “UsrDefined7” (Par 510)

43 = “Ten Ref Pct” (Par 1194)

10 = “Trim Speed” (Par 43)

27 = “UsrDefined8” (Par 511)

44 = “CloseLp Comp” (Par 1208)

11 = “Ramp In” (Par 110)

28 = “UsrDefined9” (Par 512)

45 = “Actual Comp” (Par 1213)

12 = “Ramp Out” (Par 113)

29 = “UsrDefined10” (Par 513)

46 = “W Reference” (Par 1217)

13 = “Speed Reg In” (Par 118)

30 = “UsrDefined11” (Par 514)

47 = “Encoder Spd” (Par 420)

14 = “Adaptive Ref” (Par 183)

31 = “UsrDefined12” (Par 515)

48 = “Resolver Spd” (Par 428)

15 = “Arm Cur Pct” (Par 199)

32 = “UsrDefined13” (Par 516)

16 = “SpdRegOutPct” (Par 236)

33 = “UsrDefined14” (Par 517)