Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 131

Advertising
background image

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

131

Programming and Parameters

Chapter 3

MO

TO

R C

O

NTROL

Fi

el

d Co

n

fi

g

468

[Min Fld Curr Pct]
Minimum allowable field current. The value set in this parameter also
influences the threshold at which the “Fld Current Loss” (F6) fault occurs. The
threshold is half of the value of Par 468 [Min Fld Curr Pct]. The value of Par
351 [Field Current] equals the value of this parameter when Par 499 [Field
Economy En] = 1 “Enabled” and Field Economy becomes active. Leave set to
the default value for permanent magnet motor applications.

Default:

Min/Max:
Units:

30

0 / Par 467 [Max Fld Flux Pct]
%

16-bit
Int

467,
499

469

[Field Mode Sel]
Operating mode of the field controller.
“Base Speed” = The motor field is regulated with constant current and

controls the motor from zero to base speed. If a curve is defined through
Pars 916, 917 and 918 [Fld Const xx Pct], this value will change linearly
through Par 467 [Max Fld Flux Pct] (which is a percentage of the nominal
flux value set in Par 280 [Nom Mtr Fld Amps]).

“Field Weaken” = The motor field is regulated with a combination of

torque and constant power (armature and field regulation -- field
weakening). The maximum armature voltage is configured in Par 175
[Rated Motor Volt]. When using a DC contactor, this parameter is set to
this option, and Par 458 [SpdReg FB Bypass] is set to 1 “Enabled,” the
armature voltage feedback terminals A1 and A2 must be connected to the
motor terminals A1 and A2, respectively.

“External” = The motor field power is supplied by an external rectifier/

converter (the drive’s field output is disabled).

“PM External” = External field created by a permanent magnet (PM)

motor.

Note: Option 3 “PM External” was added for firmware version 5.002.

Default:

Options:

0 =

0 =
1 =
2 =
3 =

“Base Speed”

“Base Speed”
“Field Weaken”
“External”
“PM External”

16-bit
Int

456,
916,
917,
918,
921

493

[Arm Volt Kp]
Proportional gain (K

P

) of the field voltage regulator expressed as a

percentage of the value defined in Par 495 [Arm Volt Kp Base].

Default:

Min/Max:
Units:

30.00

0.00 / 100.00
%

Real

495

494

[Arm Volt Ki]
Integral gain (K

I

) of the field voltage regulator expressed as a percentage of

the value defined in Par 496 [Arm Volt Ki Base].

Default:

Min/Max:
Units:

40.00

0.00 / 100.00
%

Real

496

495

[Arm Volt Kp Base]
The proportional gain (K

P0

) of the field voltage regulator (base value).

Default:

Min/Max:
Units:

Based on drive current rating

0.10 / Based on drive current rating
A / V

Real

493

496

[Arm Volt Ki Base]
The integral coefficient (K

I0

) of the field voltage regulator (base value).

Default:

Min/Max:
Units:

0.90 x P496

max

0.01 / Based on drive current rating
A / V / ms

Real

494

497

[Field Reg Enable]
Enables/Disables the field regulator. Leave set to the default value for
permanent magnet motor applications.
“Enabled” = The field regulator is enabled and controlling the field

output.

“Disabled” = The field regulator is disabled (the field current is zero).

Default:

Options:

1 =

0 =
1 =

“Enabled”

“Disabled”
“Enabled”

16-bit
Int

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

ATTENTION: Failure to set this parameter to a value appropriate for the intended application could result in excessive
motor speed, equipment damage, and/or personal injury.

A

A