Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 171

Advertising
background image

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

171

Programming and Parameters

Chapter 3

APPL

IC

AT

IONS

To

rq

u

e P

ro

ve

1113 [ZeroSpdFloatTime]

Amount of time the drive is at or below the speed set in Par 1111 [Float Tolerance]
before the brake is set. This parameter is not used when Par 1100 [Torq Prove Cfg]
Bit 1 “Encoderless” is set to “1” (enabled).
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:
Units:

5.0

0.1 / 500.0
s

Real

1100

1114 [Brake Test Torq]

Percent of torque applied to the motor before the brake is released when Par 1100
[Torq Prove Cfg], bit 7 “Test Brake” is set to “1” (enabled).
Note: This parameter was added for firmware version 6.001.

Default:

Min/Max:
Units:

50

0 / 150
%

Real

1100

Sca

le

B

lo

ck

s

484
553
1218
1227
1236
1245

[Scale1 Input]
[Scale2 Input]
[Scale3 Input]
[Scale4 Input]
[Scale5 Input]
[Scale6 Input]
Parameter number from which the value is read and used as the input quantity to
the Scale block. See the Scale Blocks block diagram on page

361

for more

information.

Default:

Min/Max:

0

0 / 1410

16-bit
Int

485
554
1219
1228
1237
1246

[Scale1 Output]
[Scale2 Output]
[Scale3 Output]
[Scale4 Output]
[Scale5 Output]
[Scale6 Output]
Parameter number to which the value of the Scale block output is written. See the
Scale Blocks block diagram on page

361

for more information.

Default:

Min/Max:

0

0 / 1410

16-bit
Int

486
555
1220
1229
1238
1247

[Scale1 Mul]
[Scale2 Mul]
[Scale3 Mul]
[Scale4 Mul]
[Scale5 Mul]
[Scale6 Mul]
Multiplier of the input quantity (after a possible limitation). Resolution:
5 digits. See the Scale Blocks block diagram on page

361

for more information.

Default:

Min/Max:

1.00

–/+10000.00

Real

487
556
1221
1230
1239
1248

[Scale1 Div]
[Scale2 Div]
[Scale3 Div]
[Scale4 Div]
[Scale5 Div]
[Scale6 Div]
Divisor, through which it is possible to divide the input quantity already multiplied
and limited. Resolution: 5 digits. See the Scale Blocks block diagram on page

361

for more information.

Default:

Min/Max:

1.00

–/+10000.00

Real

488
557
1222
1231
1240
1249

[Scale1 In Max]
[Scale2 In Max]
[Scale3 In Max]
[Scale4 In Max]
[Scale5 In Max]
[Scale6 In Max]
Maximum limit of the input quantity. Resolution: 5 digits. See the Scale Blocks
block diagram on page

361

for more information.

Default:

Min/Max:

0.00

– 2

31

/ +2

31

– 1

Real

489
558
1223
1232
1241
1250

[Scale1 In Min]
[Scale2 In Min]
[Scale3 In Min]
[Scale4 In Min]
[Scale5 In Min]
[Scale6 In Min]
Minimum limit of the input quantity. Resolution: 5 digits. See the Scale Blocks
block diagram on page

361

for more information.

Default:

Min/Max:

0.00

– 2

31

/ +2

31

– 1

Real

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

A

A

A

A

A

A

A

A

Advertising