Control power circuit protection fuses, Switching power supply circuit board fuses, Ee control power circuit protection fuses on – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 249: Figure 76, For f

Advertising
background image

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

249

Supplemental Drive Information

Appendix A

Figure 76 - Frame C Non-Regenerative Drive - AC Input Line Fuse Location

Control Power Circuit
Protection Fuses

Switching Power Supply Circuit Board Fuses

The following fuses are used to protect the switching power supply circuit.

Note: Drive shown with front covers removed and control board EMI shield lowered.

AC Input fuses and switches are installed on the bus bars behind the control board EMI shield.

IMPORTANT

Verify the circuit board revision prior to ordering and installing fuses.

Frame

Circuit Board ID / Revision

Designation

Fuse (5 x 20 mm)

A

SW1-31 / H & below

F1

1 A, 250V, slow

SW1-31 / I & above

F1

2.5 A, 250V, slow

B

SW2-32 / H & below

F1

3.15 A, 250V fast

F2

2.5 A, 250V slow

SW2-32 / I & above

F1

2.5 A, 250V slow

F2

C

SW3-32 / H & below

F1

3.15 A, 250V fast

F2

2.5 A, 250V slow

SW3-32 / I & above

F1

2.5 A, 250V slow

F2

D

SW1-31 / I & above

F1

2.5 A, 250V, slow

Advertising