Utility file, Param access lvl – Rockwell Automation 23P PowerFlex Digital DC Drive User Manual

Page 173

Advertising
background image

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014

173

Programming and Parameters

Chapter 3

Utility File

Fil

e

Gr

oup

No

.

Parameter Name & Description

See

page 114

for symbol descriptions

Values

Da

ta

T

yp

e

Rela

ted

UTILIT

Y

R

ef

ere

nce C

onf

ig

209

[Save HIM Ref]
Enables a feature to save the present reference value issued by the HIM to drive memory when a power loss occurs. The value is restored to the HIM at power
up.
Bit 0 - “At Pwr Down” 0 = Do not save, 1 = Save at power down

210

[Man Ref Preload]
Enables/disables a feature to automatically load the present “Auto” reference
value into the HIM when “Manual” is selected. Allows smooth speed transition
from “Auto” to “Manual.”

Default:

Options:

1 =

0 =
1 =

“Enabled”

“Disabled”
“Enabled”

16-bit
Int

249

[MOP Ref Config]
Enables/Disables the feature that saves the present MOP reference at power down or at stop.
Notes: This parameter can be assigned to a digital input. Bits 2 and 3 were added for firmware version 6.001.
Bit 0 “Save PwrDown” - When set to “0” = Do not save, “1” = Save
Bit 1 “Save At Stop” - When set to “0” = Do not save, “1” = Save
Bit 2 “Reset AtStop” - When set to “0” = No MOP reset, “1” = Reset MOP at Stop
Bit 3 “Reset At Flt” - When set to “0” = No MOP reset, “1” = Reset MOP at Fault

1322 [Direction Mode]

Selects the method that will be used for changing direction.
“Unipolar” - Drive Logic determines the direction.
“Bipolar” - The sign of the reference determines the direction.
“Rev Disable” - Forward direction only (not changeable).

Default:

Options:

0 =

0 =
1 =
2 =

“Unipolar”

“Unipolar”
“Bipolar”
“Rev Disable”

16-bit
Int

1375 [MOP Select]

Selects the destination of the MOP signal.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =

“OFF”

”OFF”
“Speed Ref A”
“Speed Ref B”
“Trim Speed”
“TB Man Ref”

16-bit
Int

Dr

iv

e M

em

or

y

211

[Param Access Lvl]
Selects the parameter display level.
“Basic” = Reduced parameter set.
“Advanced” = Full parameter set.

Default:

Options:

0 =

0 =
1 =

“Basic”

“Basic”
“Advanced”

16-bit
Int

258

[Reset Defaults]
Setting this parameter to 1 “Factory” will load the default settings in the drive
firmware.

Default:

Options:

0 =

0 =
1 =

“Ready”

“Ready”
“Factory”

16-bit
Int

302

[Language]
Selects the operating language of the drive. Only two languages are available in
the drive at any given time, English and one of the following: French, German,
Italian, Portuguese, or Spanish. The drive ships with the default language options
of English and Spanish only. The additional language files can be downloaded at:

http://www.ab.com/support/abdrives/webupdate/powerflexdc.html#

Note: This parameter was added for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =

“Not Selected”

“Not Selected”
“English”
“French”
“Spanish”
“Italian”
“German”
“Reserved”
“Portuguese”

16-bit
Int

Options

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

At

P

w

r D

ow

n

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Options

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

ser

ve

d

Re

set A

t F

lt

Re

set A

tS

top

Sa

ve

A

t S

to

p

Sa

ve

Pwr

D

ow

n

Default

x

x

x

x

x

x

x

x

x

x

x

x

0

0

0

0

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Advertising