MD65 AC Drive User Manual

9.3

Display Group Parameters

Displays the output frequency present at terminals T1, T2, and T3
(U, V, and W).

Displays the value of the active frequency command. The
commanded frequency is displayed even if the drive is not running.

Important:

The frequency command can come from a number of
sources. Refer to section 6.6, Start and Speed
Reference Control, for more information.

Displays the output current present at terminals T1, T2, and T3 (U,
V, and W).

Displays the output voltage present at terminals T1, T2, and T3 (U,
V, and W).

d001 Output Freq

Range:

0.0 to Maximum Freq (P035)

Default:

Read Only

See also:

d002, d010, P034, P035, P038

d002 Commanded Freq

Range:

0.0 to Maximum Freq (P035)

Default:

Read Only

See also:

d001, d013, P034, P035, P038

d003 Output Current

Range:

0.00 to (Drive Rated Amps x 2)

Default:

Read Only

See also:

N/A

d004 Output Voltage

Range:

0 to Drive Rated Volts

Default:

Read Only

See also:

P031, A084, A088