Rockwell Automation MD65 User Manual Version 2.0 User Manual
Page 104
![background image](/manuals/581377/104/background.png)
9-50
MD65 AC Drive User Manual
Displays the status of the communications ports.
Displays the Main Control Board software version.
Used by Rockwell Automation field service personnel.
Displays the accumulated time drive is outputting power. The time is
displayed in 10-hour increments (that is, 1 = 10 hours).
d015 Comm Status
Range:
0 = Condition False
1 = Condition True
See figure 9.19.
Default:
Read Only
See also:
A103 through A107
Figure 9.19 – Comm Status (d015) Bit Definitions
Receiving Data
Bit 0
Transmitting Data
Bit 1
RS485 Option Connected
Bit 2
Communication Error Occurred
Bit 3
d016 Control SW Ver
Range:
1.00 to 99.99
Default:
Read Only
See also:
N/A
d017 Drive Type
Range:
1001 to 9999
Default:
Read Only
See also:
N/A
d018
Elapsed Run Time
Range:
0 to 9999 Hours
Default:
Read Only
See also:
N/A