9-14

MD65 AC Drive User Manual

Determines the operation of the programmable opto outputs.

0 = Ready/Fault (A058 Default): Opto outputs are active when
power is applied. This indicates that the drive is ready for operation.
Opto outputs are inactive when power is removed or a fault occurs.

1 = At Frequency: Drive reaches commanded frequency.

2 = MotorRunning (A061 Default): Motor is receiving power from
the drive.

3 = Reverse: Drive is commanded to run in reverse direction.

4 = Motor Overld: Motor overload condition exists.

5 = Ramp Reg: Ramp regulator is modifying the programmed
accel/decel times to avoid an overcurrent or overvoltage fault from
occurring.

6 = Above Freq: Drive exceeds the frequency (Hz) value set in
Opto Outx Level (A059 or A062). Use A059 or A062 to set the
threshold.

A058
A061

Opto Out1 Sel
Opto Out2 Sel

Range:

0 = Ready/Fault
1 = At Frequency
2 = MotorRunning
3 = Reverse
4 = Motor Overld
5 = Ramp Reg
6 = Above Freq
7 = Above Cur
8 = Above DCVolt
9 = Retries Exst
10 = Above Anlg V
11 = Logic In 1
12 = Logic In 2
13 = Logic 1 & 2
14 = Logic 1 or 2
15 = StpLogic Out
16 = Timer Out
17 = Counter Out
18 = Above PF Ang
19 = Anlg In Loss
20 = ParamControl
21 = NonRec Fault
22 = EM Brk Cntrl

Default:

A058: 0 = Ready/Fault
A061: 2 = MotorRunning

See also:

A056, A092, A140-A147, A150-A157, P033