Parameter Descriptions

9-43

Sets the time to remain in each step if the corresponding StpLogic
command word is set to “Step after Time.”

Figure 9.13 – Digit Settings

Logic For Next Step

Digit 0

Logic to Jump to a Different Step

Digit 1

Different Step to Jump

Digit 2

Step Settings

Digit 3

Digit 3 Settings

Required

Setting

Accel/Decel

Param. Used

StepLogic

TM

Output State

Commanded

Direction

0
1
2
3
4
5
6
7
8
9
A
b

Accel/Decel 1
Accel/Decel 1
Accel/Decel 1
Accel/Decel 1
Accel/Decel 1
Accel/Decel 1
Accel/Decel 2
Accel/Decel 2
Accel/Decel 2
Accel/Decel 2
Accel/Decel 2
Accel/Decel 2

Off
Off
Off
On
On
On
Off
Off
Off
On
On
On

FWD

REV

No Output

FWD

REV

No Output

FWD

REV

No Output

FWD

REV

No Output

Digit 2 Settings

Digit 1 and Digit 0 Settings

0 = Jump to Step 0
1 = Jump to Step 1
2 = Jump to Step 2
3 = Jump to Step 3
4 = Jump to Step 4
5 = Jump to Step 5
6 = Jump to Step 6
7 = Jump to Step 7
8 = End Program (Normal Stop)
9 = End Program (Coast to Stop)
A = End Program and Fault (F2)

0 = Skip Step (Jump Immediately)
1 = Step Based on (Stp Logic Time x)
2 = Step if “Logic In1” is Active
3 = Step if “Logic In2” is Active
4 = Step if “Logic In1” is Not Active
5 = Step if “Logic In2” is Not Active
6 = Step if either “Logic In1” or “Logic In2” is Active
7 = Step if both “Logic In1” and “Logic In2” is Active
8 = Step if neither “Logic In1” or “Logic In2” is Active
9 = Step if “Logic In1” is Active and “Logic In2” is Not Active
A = Step if “Logic In2” is Active and “Logic In1” is Not Active
b = Step after (Stp Logic Time x) and “Logic In1” is Active
C = Step after (Stp Logic Time x) and “Logic In2” is Active
d = Step after (Stp Logic Time x) and “Logic In1” is Not Active
E = Step after (Stp Logic Time x) and “Logic In2” is Not Active
F = Do Not Step/Ignore Digit 2 Settings

A150
A151
A152
A153
A154
A155
A156
A157

Stp Logic Time 0
Stp Logic Time 1
Stp Logic Time 2
Stp Logic Time 3
Stp Logic Time 4
Stp Logic Time 5
Stp Logic Time 6
Stp Logic Time 7

Range:

0.0 to 999.9 sec

Default:

30.0 sec

See also:

P038, A055, A058, A061, A070-A077, A140-A147