Rockwell Automation MD65 User Manual Version 2.0 User Manual

Page 72

Advertising
background image

9-18

MD65 AC Drive User Manual

Scales the Maximum Output Value for the Analog Out Sel (A065)
source setting.

For example:

Sets the rate of acceleration for speed increases except jog. Refer
to the flowchart in figure 6.3 for details. Refer to figure 9.3.

Maximum Frequency / Accel Time = Accel Rate

Sets the rate of deceleration for speed decreases except jog. Refer
to the flowchart in figure 6.3 for details. See figure 9.4.

A066 Analog Out High

Range:

0 to 800%

Default:

100%

See also:

A065

A066 Setting

A065 Setting

A065 Max. Output Value

50%

1 = OutCurr 0-10

5 V for 200% Drive Rated Output Current

90%

8 = OutPowr 0-20

18 mA for 200% Drive Rated Power

A067 Accel Time 2

Range:

0.0 to 600.0 sec

Default:

10.0 sec

See also:

P039, A051-A054, A070-A077, A140-A147

Figure 9.3 – Accel Time 2 (A067)

Speed

0

Time

P035 [Maximum Freq]

P039 or A067

[Accel Time x]

P040 or A068

[Decel Time x]

0

Acceleration

D

ecelera

tion

A068 Decel Time 2

Range:

0.1 to 600.0 sec

Default:

10.0 sec

See also:

P040, A051-A054, A070-A077, A140-A147