Parameter Descriptions

9-19

Maximum Frequency / Decel Time = Decel Rate

Provides the frequency command to the drive when Speed
Reference (P038) is set to 1=Internal Frequency. When enabled,
this parameter will change the frequency command in “real time”

using the integral keypad

keys when in program mode.

Important:

Once the desired command frequency is reached, the

key must be pressed to store this value to

EEPROM memory. If the

key is used before the

key, the frequency will return to the original value

following the normal accel/decel curve.

If Digital Inx Sel (A-051-A054) is set to 16 = MOP Up or 17 = MOP
Down, this parameter acts as the MOP frequency reference.

Figure 9.4 – Decel Time 2 (A068)

Speed

0

Time

P035 [Maximum Freq]

P039 or A067

[Accel Time x]

P040 or A068

[Decel Time x]

0

Acceleration

D

ecel

era

tion

A069 Internal Freq

Range:

0.0 to 400.0 Hz

Default:

0.0 Hz

See also:

P038

PROG