8-2

MD65 AC Drive User Manual

8.1.1 Display Description

The alpha-numeric display indicates the following:

•

Parameter number

•

Parameter value

•

Fault code

8.1.2 LED Descriptions

Refer to figure 8.1 for the location of the LEDs described in table
8.1.

Table 8.1 – LED Descriptions

No.

LED

LED State

Description

➊

RUN

Steady Red

Indicates the drive is running.

➋

FWD
REV

Flashing
Red

Drive has been commanded to
change direction. Indicates actual
motor direction while decelerating
to zero.

Steady Red

Indicates the commanded motor
direction.

➌

VOLTS
AMPS
HERTZ

Steady Red

Indicates the units of the
parameter value being displayed.

➍

PROGRAM

Steady Red

Indicates the drive is in program
mode and the parameter value
can be changed.

➎

FAULT

Flashing
Red

Indicates the drive is faulted.

➏

Pot Status

Steady
Green

Indicates the potentiometer on
integral keypad is active.

➐

Start Key Status

Steady
Green

Indicates the Start key on integral
keypad is active. The Reverse key
is also active unless disabled by
A095 (Reverse Disable).