Library Shapes

229

Base Width
Enter the width of the rectangular base of the part.

Base Height
Enter the height of the rectangular portion of the part.

Left Convex Radius
Enter the length of the radius of the left convex side of the part.

Right Convex Radius
Enter the length of the radius of the right convex side of the part.

Top Convex Radius
Enter the length of the radius of the top convex side of the part.

Bottom Convex Radius
Enter the length of the radius of the right convex side of the part.

Corner Size
Enter the length and height of the corners of the part.

Lead-In/Lead-Out Length
Enter the appropriate value to ensure proper piercing (lead-in) and gas bleed-off (lead-
out) to obtain optimum cut quality.

The location for the lead-in and lead-out is fixed, but can be changed by using the
ShapeWizard and then saving the new shape to disk.