Command THC

435

Release

Press the Release soft key to end a pierce cycle but keep the original pierce time.

Diagnostics


The current Command THC Interface and Real Time Revision Levels are displayed at the
Control Information screen when enabled.

Machine Interface

Warning! Configure the port for RS-422 operation before connecting to the

Command THC. The Command THC Link must first be enabled in Machine Setups for
Type “P” controls and at the Station configuration for type “V” controls. Refer to the
Serial Port section of this guide for additional information on configuring the serial port
for RS-422 communication.

Port Designation

Serial communication for the Command THC is automatically set to the serial port which
is not selected for serial communications. For example, if Serial Port 1 is designated for
use as the link to the host PC for downloading part programs, HD4070

communications

are established on Serial Port 2.

Type “V” control may select the serial port designation at the Ports configuration screen.

RS-422 Connections to Command THC with 25-pin D-type connector


Command

THC

Control

Signal Name

DB-9 Pin

Signal Name

DB-9 Pin

RxD -

1

TxD -

2

TxD -

2

RxD -

3

RxD +

20

TxD +

4

TxD +

21

RxD +

7


For improved noise immunity, cable shields for communication should be tied to ground.
Ferrite bead with several wraps on the cable may also be used.