Password Setups

368

Axes -- SERCOS
The SERCOS Interface controls the position loop from the amplifier. As a result, limited
information for motion is required in the CNC setups. Tuning is performed through
serial port diagnostic software available at the Drives & Motors Diagnostic screen.


The following is a listing of the unique SERCOS parameters. Note: parameters will
apply to all SERCOS axes.

SERCOS Drive Address
Each Drive Axes is automatically assigned a Drive Address at the CNC. The appropriate
drive amplifier will be coded with the matching Drive Address to provide control motion
to the correct amplifier / motor on the SERCOS ring.

Note: The drives may be physically located in any order on the ring.

Emulated Encoder Counts/ motor rev
This parameter allows the user to adjust the number of counts per motor rev that the drive
generates over the SERCOS ring, to adjust resolution. This parameter is available for Pac
Sci drives only. Other drive types allow the emulated Counts /motor rev parameter to be
set up in the drive tuning software.