Password Setups

349


Expanded I/O
Available when more than 64 I/O have been selected. A drop-down box is available to
assign I/O in the higher I/O ranges.

Note: When the optional USB front panel is used, the top 128 I/O are assigned to USB
I/O to support the front panel

Input Logic
The CNC comes standard with up to 32 discrete inputs. Used as a mask to determine
whether an input is treated as a normally open or closed contact. Entering a numerical
value here sets all the Inputs to a predefined set of logic states for all of the inputs.

With Input Logic set to zero (0), an active input is displayed with a green lamp in the
input diagnostic screen.

Logic Selection Box
Determines whether the logic state for each input is normally open or closed. To select
the logic state for an input, select the desired input and press the space key.