Reset Button:
SW5 – Press to reset card

Error Codes:
E1 Display Code = "Voltage or Temperature Error Detected!"
Displayed if voltage or temperature sensors on Field Interface board indicate an error.
Please check power supply, wiring and connections.

E2 Display Code = "Bad Checksum for SMCC Software!"
Displayed if checksum for SERCOS Slave Flash Program is not correct. Program needs
to be reloaded using the Serial Port connection.

E3 Display Code = "Wrong Interface Board Detected for Selected SERCOS
Address!"
Displayed if the selected SERCOS Slave Address/SERCOS Slave mode does not match
the Field Interface functionality. For example, using an HPR Field Interface with a
SERCOS Slave card set to Drive Address 1-12 is not possible, since these are axes
SERCOS addresses only, not peripheral I/O SERCOS addresses.