Hypertherm Phoenix 8.0 User Manual

Page 462

Advertising
background image

Program Codes

455

11B

Mapped EIA Codes

47B

47B 47B

47B

EIA CODE

DESCRIPTION

MAPPED TO

G04 Fvalue

Program Dwell

G04 Xvalue

G05

Set Axis Presets

G92

G21

Linear Interpolation

G01

(at cut speed)

G22

CW Circular Interpolation

G02

G23

CCW Circular Interpolation G03

G41 Kvalue

Left Kerf with Value

G41 with Kerf Value

G42 Kvalue

Right Kerf with Value

G42 with Kerf Value

G97 TValue

Subroutine Loop

G08 Xvalue and M40

G45

Lead In to Kerfed Part

G01, G02, or G03

G70

Select English Units

G20

G71

Select Metric Units

G21

G98

End of Subroutine Loop

M41

M03

Cutting Device On/Off

M07 (Oxy Fuel) or M08 as appropriate

M04

Cutting Device On

M07

M05

Cutting Device Off

M08 (Oxy Fuel)

M06

Cutting Device Off

M08

M06

Enable Marker 2

M13

M07

Disable Marker 1 or 2

M10 or M14 as appropriate

M08

Enable Marker 1

M09

M09

Disable Marker 1 or 2

M10 or M14 as appropriate

M10

Enable Marker 2

M13

M14

Height Sensor Disable

M50

M15

Height Sensor Enable

M51

M20

Cutting Device On/Off

M07 or M08 as appropriate (Plasma)

M21

Cutting Device On/Off

M07 or M08 as appropriate (Plasma)

M20

Output 9 On

O9 S1

M21

Output 9 Off

O9 S0

M22

Output 12 On

O12 S1

M23

Output 12 Off

O12 S0

M24

Wait for Input 7 On

W7 S1

M25

Wait for Input 8 On

W8 S1

M25

CBH Enable

M29

M26

Wait for Input 7 Off

W7 S0

M26

CBH Disable

M28

M27

Wait for Input 8 Off

W8 S0

M67, M02

Kerf Left

G41

M68, M03

Kerf Right

G42

M69, M04

Kerf Off

G40

M65, M70

Cutting Device On

M07

M66, M71, M73

Cutting Device Off

M08

M70

Marker Offset 1 Off

M12

M71

Marker Offset 1 On

M11

M70T01

Marker Offset 1 Off

M12

Advertising