Hypertherm Phoenix 8.0 User Manual

Page 313

Advertising
background image

Manual

306

Rail

Press the Rail soft key to initiate the automated homing procedure. This procedure
generally produces machine motion in the Rail axis, depending on the homing parameters
set in the Setups.

CBH

Press the CBH soft key to initiate the automated homing procedure. This procedure
generally produces machine motion in the CBH axis, depending on the homing
parameters set in the Setups.

THC

Press the THC soft key to initiate the automated homing procedure for the Sensor THC.
This procedure generally produces machine motion in the THC axis, depending on the
homing parameters set in the Setups.

Tilt

Press the Tilt soft key to initiate the automated homing procedure for the Tilt Axis.

Rotate

Press the Rotate soft key to initiate the automated homing procedure for the Rotate Axis.
Note: If Tilt and Rotate Axes are enabled, the following window will appear and allow
access to the Tilt/ Rotate or other axes.


Select Yes to access Homing for the Tilt and Rotate Axes. Select No to access the
Homing functions for the other axes,

All

Press the All soft key to initiate the automated homing procedure. This procedure
generally produces machine motion in one or more axes, depending on the homing
parameters set in the Setups.

Go To Home Position

Press one of the four Go To Home Position soft keys to move the transverse and rail axes
to the predefined position set in the corresponding edit window. The Go To Positions are
absolute and require that an automated home procedure already be executed.

Advertising
This manual is related to the following products: