Hypertherm Phoenix 8.0 User Manual

Page 57

Advertising
background image

Setups

50

3.

When you finish selecting controls and assigning outputs, press or click OK.
When you return to the Oxy Fuel screen, the parameters for the control you selected
are added to the screen.

4.

Edit the values for the parameters to meet the needs of your process.

Oxy Torch Pressures

Select the type of oxy fuel torch for the process.

Oxy Cut Pressure

Enter the pressure, in pounds per square inch, of the oxy fuel during cutting.

Oxy Ramp Up Time

Enter the time, in seconds, that the oxy fuel takes to reach cutting pressure.

Preheat Low Pressure

Enter the pressure, in pounds per square inch, of the oxy fuel at low pressure during
preheat.

Preheat High Pressure

Enter the pressure, in pounds per square inch, of the oxy fuel at high pressure during
preheat.

Preheat Pressure

Enter the preheat pressure, in pounds per square inch, for the triple bevel head.

Preheat Ramp Up Time

Enter the number of seconds that the process takes to move from low to high pressure
during preheat.

Preheat Ramp Down Time

Enter the number of second that the process takes to move from high to low pressure
during preheat.

Fuel Low Pressure

Enter the pressure, in pounds per square inch, of the oxy fuel at low pressure during
cutting.

Fuel High Pressure

Enter the pressure, in pounds per square inch, of the oxy fuel at high pressure during
cutting.

Fuel Pressure

Enter the fuel pressure, in pounds per square inch, for the triple bevel head.

Fuel Ramp Up Time

Advertising