Pause – Hypertherm Phoenix 8.0 User Manual

Page 296

Advertising
background image

289

Pause

If the cut process fails, the CNC has full-featured recovery capabilities.
The Cut Loss Recovery features of the CNC are available from the Pause screen which
displays when the operator presses Stop or if cut sense is lost.


Press the Cancel key while the Pause screen is displayed to cancel the current part.

Return to Start
Allows the operator to return to the initial starting point of the part. Note: If the Return
to Start function is used after a cut loss, all information about the current position of the
cutting device on the path is lost.

Backup and Forward on Path
Use these two soft keys to move backward and forward along the cut path at the selected
move speed to locate the pierce restart point. Press the Start key to resume the cut at the
programmed cut speed. In addition to all segments of a standard part, the Backup and
Forward on Path functions allow full movement through all sections of Shape Repeat
part, as well.

Advertising