Hypertherm Phoenix 8.0 User Manual

Page 515

Advertising
background image

Automated Plasma Interface

508

Note: Screen information will vary depending on THC selection.

Cut Chart

The Cut Chart Database (cut process parameters) transmitted to the power supply is based on the
following eight process variables.

Material Type

The Material Type, such as Mild Steel, Stainless Steel or Aluminum, may be selected.

Specific Material

A custom database from the dropdown list may be selected. The factory default is None.

Current Settings

The appropriate current setting for the material thickness and material type may be selected.

Plasma / Shield Gases

The appropriate Plasma / Shield gases for the desired process may be selected.