Setups

79

Pulse Laser Power

Sets the Laser Pulse Power for a one shot beam alignment.

Height Control Manual/Automatic

Allows the user to either select a Manual or Automatic Height control for the laser head.

IHS in Manual

The IHS in Manual setup parameter allows the operator to select whether or not to use the
Initial Height Sense feature when operating the Z axis lifter (THC1) in manual mode.

Retract Full/Partial

Selects the retract distance to be set at Full or Partial. In the Full retract mode, the laser
head will retract to the Z-Axis Home position. In Partial retract mode, the laser head will
retract to the set retract distance.

Partial Retract Distance

This setup parameter is used to select the THC 1 Retract Distance when configured for
partial retract mode.

Start IHS Distance

The Start IHS Distance specifies the distance of travel for the THC 1 to move the laser
head at high speed before switching to low speed and beginning Initial Height Sense.
Caution should be taken when selecting this distance so that the laser head does not crash
into the plate.

Preflow During IHS

Selecting ON will activate Preflow gases during the IHS cycle.

Nozzle Contact IHS

This parameter would be set to ON to select the THC 1 to use Contact Sense to detect the
plate during the IHS cycle.

Nozzle Contact During Cut

Nozzle Contact During Cut allows the CNC to detect contact with the plate and generates
a fault if this condition occurs.

Pierce Control Manual/Automatic

Allows the user to select manual or automatic pierce control. Automatic control uses
sensors in the Laser head to detect when the pierce is complete. Manual mode uses a
preset pierce time and preset laser program. Automatic mode dynamically controls laser
duty cycle.

Pierce Mode Pulse/Blast

When Automatic Pierce is selected the user can select to use a definable pulse output or a
single Blast.