554


Shared Inputs
Note that general inputs #11 and #12 are shared with the Lifter Interface Limit Switch
inputs. These inputs can only be used as general purpose inputs if they are NOT used by
the Lifter limit switches.

If you are using the Lifter Interface and limit switches are connected to these inputs you
must set DIP switches SW1-1 and SW1-2 to ON and you should not connect to inputs
#11 and #12. Note that the standard Hypertherm Lifter does not use limit switches and
the DIP switches SW1-1 & SW1-2 should be OFF so that inputs #11 and #12 can be
used.


Switch SW1-1 and SW1-2


I/O Mating Connector
The I/O connector is a standard sex circular CPC connector from AMP
Connector AMP 16C #206037-1
Backshell AMP #206070-1
Sockets 20-24AWG AMP #66105-3


I/O Setup Screen
The I/O setup screen is used to define inputs, outputs and their logic state.