Hypertherm Phoenix 8.0 User Manual

Page 69

Advertising
background image

Setups

62

Save Process

Pressing the Save Process soft key allows the user to save the current process settings to
the hard drive and create a custom user database based on the eight process variables
selected.

Reset Process

Pressing the Reset Process soft key allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.

Save Cut Charts

Pressing the Save Cut Charts soft key allows the user to save the current User and
Factory databases to Diskette or USB memory stick. User files are designated with a .usr
file extension and the factory files are designated with a .fac file extension

Examples of user and factory file names:

Mild Steel-HT4400-HD4070.usr
Mild Steel-HT4400-HD4070.fac

Load Cut Charts

Pressing the load Cut Charts soft key allows the user to load the factory default database
files which are supplied by Hypertherm in a Text file (.txt), user files (.usr) or factory
files (.fac) from Diskette or USB memory stick.

Factory text file names:

Mild Steel Cut Chart Data

mschart.txt

Aluminum Cut Chart Data

alchart.txt

Stainless Steel Cut Chart Data

sschart.txt


It is recommended that the Database be updated through the control rather than the Power
Supply if the serial communications link is enabled.

Test Preflow

Pressing the Test Preflow soft key performs the Test Preflow Gases feature at the Plasma
supply.

Test Cutflow

Pressing the Test Cutflow soft key performs the Test Cutflow Gases feature at the Plasma
supply.

Notes:

Refer to the power supply operator’s manual for complete information on the
operation and setup of the plasma supply.

A serial communication port for the plasma supply must first be selected at the port
configuration screen to be enable the feature for use.