110

ALARM_RESET

G

ROUP

Fault_Manager

S

YNTAX

ALARM_RESET

O

P

. C

ODE

167

M

ODES

Program

D

ESCRIPTION

Resets the current alarm from the alarm buffer. The list of

alarms can be found at the FSP Amplifier’s User’s Manual
(See document number YEA-SIA-FSP-3). The
ALARM_RESET can only reset alarms not marked with *. If

the command is used to clear other alarms the program will
be stopped.

E

XAMPLE

LABEL 5
TORQUE_ANALOG


FAULT_MANAGER
ALARM_RESET
SET_OUTPUT 1 ON
DELAY 1000
SET_OUTPUT 1 OFF
FAULT_MANAGER_RETURN 5

E

XAMPLE

E

XPLANATION

When an alarm occurs (for example, over torque in this
case), the program jumps to the fault manager, resets the
alarm (if possible) and toggles an output.

S

EE

A

LSO

FAULT_MANAGER_RETURN, FAULT_MANAGER
Variables: Fault_code, Fault_line