Serial Interface Protocol

199

6.

Serial Interface Protocol

This chapter describes the FSP Amplifier serial communication
protocol. FSP Amplifier can work with FlexWorks or with any other
software that complies with this protocol. Up to 15 FSP Amplifier

units can be connected on a bus. Broadcast commands can be sent
to all axes (FSP Amplifier units).

6.1. Basic Communication Specifications

Half duplex communication using the following:

Baud rate:

19200

Auto-detect

Bit Structure:

Start

1 bit

Data

7 bit (ASCII code)

Stop

1

bit

Even-number parity 1 bit

Synchronization: Start / Stop

synchronization

1 bit

6.2. Protocol

Specifications

In this master/slave protocol, a PC (or other device) is the master
and the FSP Amplifier is the slave. The master sends a request or a

polling message, and the FSP Amplifier answers with a response
message. The master can only send a new message after receiving
an answer or ACK (acknowledge) message or after timeout has
expired.
The master can control up to 15 FSP Amplifier units by using

addresses. When broadcast messages are sent, the master does
not wait for an ACK.
When there is no command to send, the master can continue
sending polling messages; the FSP Amplifier responds with an ACK.
The diagram below illustrates the communication protocol between

a PC (master) and a single FSP Amplifier.