Serial Interface Protocol

207

6.2.3. Response Message

All master messages, except broadcast messages, are responded to
by an FSP Amplifier response message.
Format:

N A

M

I

D

1 I

D

2 A

NSWER

S1 S2 CR

Where:

Description: FSP Amplifier message start symbol. Constant value.

N

Range: N

Description: Axis address. The response message holds the same
axis address as the original message.

A

Range: 0x0 – 0xF

Description: Response type.

M

Range: 0 – Acknowledge (without Fault)
1 – Acknowledge (with Fault)
2 – Response for data request command
3 – Acknowledge with watch variables field
5 – Program upload
Description: Message Identification in case of Fault (Response
type, m = 1). Otherwise (no fault) the Message Identification is set
to 0x00 (two bytes for two digits). If a fault is related to a specific

command / message, Id1 and Id2 contain the Message Identification
as sent by the master.
Since the range is greater than 0xF, two bytes are required for
holding the number.

I

D

1

AND

I

D

2

Range: 0x0 – 0xFF. 0x0 – 0xF each

A

NSWER

Description: FSP Amplifier response. Can hold acknowledge (ACK)
or value as response to Data Request Commands such as GET_VAR.
The format of ACK and Data Request Commands are described
below.