Parameter Reference

234

Parameter

Digit

Place

Name

Setting

Description

Default
Setting

0

Sign + pulse, positive logic.

1

CW + CCW, positive logic.

2

A phase + B phase (x1), positive logic.

3

A phase + B phase (x2), positive logic.

4

A phase + B phase (x4), positive logic.

5

Sign + pulse, negative logic.

6

CW + CCW, negative logic.

7

A phase + B phase (x1), negative logic.

8

A phase + B phase (x2), negative logic.

0

Reference
Pulse Form

9

A phase + B phase (x4), negative logic.

0

0

Clears error counter when the signal goes
high.

1

Clears error counter at the rising edge of the
signal.

2

Clears error counter when the signal goes low.

1

Error Counter
Clear Signal
Form

3

Clears error counter at the falling edge of the
signal.

0

0

Clears error counter at the base block.

1

Does not clear error counter. (Possible to clear
error
counter only with CLR signal).

2

Clears error counter when an alarm occurs.

2

Clear
Operation

3

Clear signal ignore

0

0

Reference input filter for line driver signals.

Pn200

Position Control References Selection Switches

3 Filter

Selection

1

Reference input filter for open collector signals.

0

0

Doesn’t use check sum

0 Check

Sum

1

Use check sum

1

1

Communication
definitions

0

Default comm. setting (1 Start, 7 data, Even-
parity)

0

2 Not

used

Pn2C6

Communicati

on Switch

3 Not

used

0 Disabled.

0

Notch Filter
Selection

1

Uses a notch filter for torque reference.

1
2

Pn408

T

orque

Control

F

unction

Switches

3

Not used.

0