Wait_exact – Yaskawa FSP Amplifier FlexWorks User Manual

Page 186

Advertising
background image

Command Reference

186

WAIT_EXACT

G

ROUP

Wait

S

YNTAX

WAIT_EXACT <n>

O

P

. C

ODE

145

M

ODES

Program, Sequential

D

ESCRIPTION

Waits until the position error is smaller than the
motion_end_window and theoretical motion is over
(velocity_demand_value is equal to zero) or the time
limit is exceeded before proceeding to the next
command. Motion_end_window is set by the Pn2C0
parameter in user position units.
Unlike the Exact_mode flag, the WAIT_EXACT
command causes a one-time delay only.

S

YNTAX

A

RGUMENTS

n

The time period to wait. Setting this value to
–1 specifies that the program must wait for
an infinite period of time, i.e., until the
motion ends.
[ms]

Serial 4 V

E

XAMPLE

LABEL 1

MOVE 10800 3000
SET_OUTPUT 2 ON

WAIT_EXACT –1
SET_OUTPUT 1 ON
END

E

XAMPLE

E

XPLANATION

Motor starts to move; output 2 is set ON; motion
continues; when motion ends output 1 is set ON. (The
WAIT command pauses execution of the following

lines of the program until the motion is complete.)

S

EE

A

LSO

Variables: Exact_mode, Motion_end_window,
Position_error
Parameter: Pn2C0

Advertising