Yaskawa FSP Amplifier FlexWorks User Manual

Page 170

Advertising
background image

Command Reference

170

E

XAMPLE

E

XPLANATION

Current Position is set to zero; slide motion takes place
until the position value equals or exceeds 10000uu (the
WAIT_VAR command stalls the execution of the next
command). When the position value equals or exceeds
10000uu, the SLIDE 0 command “stops” (tells the motor

to move at 0 speed); the motor output 2 is set ON; End
of program.

S

EE

A

LSO

SET_OUTPUTS

Advertising
This manual is related to the following products: