background image

Operating the FSP Amplifier Using FlexWorks

34

Pulse Train:

Set the following if your application requires pulse-train
values. Otherwise skip this screen.

Pulse-train form and logic.

Electronic Gear (See section 12.1.) between the pulse-

train and the motor. (See Electronic Gear in the
Glossary.)

If position control (Pn000.1 = C) is set, the Position

Completed Width screen is enabled. When using
programming mode (Pn000.1 = D), the equivalent value

is set by Pn2C4 (Pulse train synchronization window).

Inputs:

Allocate digital inputs to system functions. Digital inputs

used as general purpose inputs can be simply referred to
by their input numbers from within the program.

The polarity can be reversed by checking the Reverse

polarity checkbox.

Outputs:

Allocate digital outputs to system functions. If digital

outputs are to be used as general-purpose outputs,
simply refer to the output number in the program.

Each output can be used either as a system function

output or as a general-purpose output.

Encoder Output Settings:

In case of a host controlled application where output pulses
(PG out) are required, set the output gear. Otherwise skip

this screen.

3. Click Finish to complete the setup and create a parameters

file.

4. Click Download Parameters to download the parameters

to FSP Amplifier.

5. Cycle the power, or click RESET to reset the FSP

Amplifier.

6. You can now proceed to Auto-tuning (See 4.6, Tuning the

Control Loops).