244

Name

Var

ID

(Dec)

Unit

Read /

Write

Min

Max

Description

U.T

1

Group

Motion_go 24

R/W

0

1

Indicates whether a motion
command is being delayed
by a WAIT_FOR_START
command and is waiting
for a START command
before executing: 0:
Motion commands are not
waiting, 1: Motion
commands are waiting.

C Status

Motion_mode 23

R

-7

7

Motion mode: 0:
SPEED_CONTROL, 1:
POSITION, 3: VELOCITY,
4: TORQUE, 6: HOMING,
-1: HUNTING, -3:
PULSE_TRAIN, -4:
ANALOG_SPEED, -
5: ANALOG_TORQUE, -7:
ECAM

C Status

Motion_status 65

R

0

3

Motion status indicator.
0: Not in motion.
1: Stopped by registration.
2: Motion stopped but not
in registration requested
position.
3: Still in motion.

2 Status

Outputs_State 34

R

-2147483648

2147483647

Output ports state. The
right-most digit is not in
use. For example, when
Outputs_State is 010, only
output 1 (CN1-25/26) is
on. Only outputs that are
set by commands are
monitored, including the
/Fast Output embedded
function. Other embedded
output functions are not
reflected by this variable.

2 Digital

I/O

Override New Move Enable

58

R/W

0

1

Specifies the functioning of
New Move Enable digital
input (Pn2D1.1). 0: Input
functions as setup; 1: Input
ignored.

2 System

Profile

Position_actual_value 9

Position
Units

R -2147483648

2147483647

Actual position.

2

Position
Variables

Position_demand_value 8

Position
Units

R -2147483648

2147483647

Theoretical position.

2

Position
Variables

Profile_acceleration 5

Acceleration
Units

R/W 0

2147483647

Acceleration value while
running motion
commands.

C System

Profile

Profile_velocity 3

Speed Units R/W

0

2147483647

Speed while running
motion commands.

C System

Profile

Program_line 45

R

1

2147483647

Holds the last program line
number.

2 Status

Pulse_train_counter

14 Counts

R/W

-2147483648

2147483647

Continuously counts the
pulses in pulse-train input

Can be Set by SET_VAR
command.

2 Position

Resonance_frequency

56 Hz R 0

65535

System resonance
frequency. Only applicable
to rotary motors.

- Status

Reverse_Torque_limit 20

0.1 % of
max

R/W -1000

1000

Maximum torque to be
applied, in reverse
direction. The maximum
torque or force is set by
Pn403 or Pn484
respectively.

C