Error Messages

223

C

ODE

M

ESSAGE

D

ESCRIPTION

speed.

133

Final target too big

If a new target position is sent

with a MOVE_H command, an
overflow may occur. The motor
must first be stopped and only
then can the motion continue.

134

Speed too low.

The speed is too low for specified
motion.

135

SET_VAR: Variable value out of
range

The variable value in command
SET_VAR is out of range.

136

Program flow error

Program flow error: RETURN
without CALL or CALL nesting too
deep.

137

Moving time is too short with
present profile Jerk time

The specified jerk time exceeds
the maximum of 64000 ms.

139

Home sensor not defined

The Home sensor is not defined.
Refer to the HOME_SW and

HOME_SW_C commands in this
manual.

140

Motion cannot be executed while
CONTROL_OFF

The motion cannot be executed
while the motor is disabled. Make
sure the motor is enabled
(CONTROL_ON) before issuing
the motion command.

141

TORQUE LIMITS: Invalid torque

limits

The maximum torque limit is

smaller than the minimum torque
limit.

142

Invalid or duplicated label

The label number is either zero or
greater than the maximum line
number.

143

Invalid input number

The input referred to in the
command is not defined as an
event.

144

Invalid output number

Invalid output index in the
SET_OUTPUT command.

146

Auto-tuning already in progress

The Auto-tuning process is
already in progress. It cannot be
restarted until the process ends.

149

Unable to switch CONTROL_ON

Advertising