Polling save_prg_ecam set_par, Polling, Save_prg_ecam – Yaskawa FSP Amplifier FlexWorks User Manual
Page 197: Set_par
Advertising

Table of Contents
197
POLLING
S
YNTAX
POLLING
O
P
. C
ODE
0
M
ODES
Immediate
D
ESCRIPTION
Reads FSP Amplifier status. For details, see Chapter
SAVE_PRG_ECAM
S
YNTAX
SAVE_PRG_ECAM
O
P
. C
ODE
96
M
ODES
Immediate
D
ESCRIPTION
Saves program and ECAM table to the EPROM for
further use after power up.
SET_PAR
S
YNTAX
SET_PAR <parameter number> <value>
O
P
. C
ODE
80
M
ODES
Immediate, Sequential.
D
ESCRIPTION
Sets FSP Amplifier parameter. The drive must be reset
before the change takes effect.
parameter number
FSP Amplifier parameter (see
Chapter 5, Parameter
Reference).
Serial 2 U
S
YNTAX
A
RGUMENTS
value
Sets value to specified
parameter. For setting range
see Chapter 8, Parameter
Reference.