Graph settings, Show, Caption – Yaskawa FSP Amplifier FlexWorks User Manual

Page 52: Chart toolbar, Graph, Settings, Show 4.7.1.4. caption 4.7.1.5. chart, Toolbar

Advertising
background image

Operating the FSP Amplifier Using FlexWorks

52

4.7.1.2. Graph Settings

For all of the graph settings described below, you can select the
scale (available values are 1, 2, 5, 10, 25, 50, 100, 500, 1000) and
the color in which the results will be displayed.
X – Sampling Time Interval

Specifies the time interval for obtaining trace data (default:
25ms). The total trace time for which results are obtained is the

sampling time interval multiplied by 10.

Y1 / Y2 – Sampled Channel

Available values are:

Target Speed

Smoothed Target Speed

Acceleration

Motor Speed

Position Error

Torque Reference

I/O 1 / I/O 2 – Sampled Digital I/O

Select the sampled output and input signals.

4.7.1.3. Show

Select the objects that will be displayed in the graph.

4.7.1.4. Caption

Enter the caption to be displayed in the graph.

4.7.1.5. Chart Toolbar

The chart toolbar is shown below.

Figure 27: Chart Toolbar

The toolbar icons are explained in the following table.

Advertising