Command Reference
194
ECAM_SEGMENT
S
YNTAX
ECAM_SEGMENT <Master Delta> <Master Step> <N/A>
O
P
. C
ODE
125
M
ODES
Immediate
D
ESCRIPTION
Defines the range and size of increments of master in
this segment. Must be sent at the beginning of each
segment.
<Master Delta>
Defines the relative distance
between the start point and the
end point of a segment. Units
are according to the electronic
gear (See section 12.1.).
Serial 4 U
<Master Step>
Defines the table increment in
master pulses. To each
increment there is equivalent
slave value so it determines the
ECAM table resolution. Units are
according to the electronic gear
(See section 12.1.).
Serial 2 U
S
YNTAX
A
RGUMENTS
<N/A>
Currently not in use. Send 1 byte
with 0 value.
Serial 1 U
S
EE
A
LSO
ECAM_TABLE_BEGIN; ECAM_PROFILE; ECAM_POINTS;
ECAM_TABLE_END