List of system variables, Variable. see chapter 9, list of system variables, 9, list of system variables – Yaskawa FSP Amplifier FlexWorks User Manual

Page 241: List of system variables 241

Advertising
background image

List of System Variables

241

9. List of System Variables

Name

Var

ID

(Dec)

Unit

Read /

Write

Min

Max

Description

U.T

1

Group

Absolute_position_error 61

Position
Units

R 0

2147483647

The absolute value of
Following_actual_value.

2

Position
Variables

Analog_Speed 42

0.1 % of
max

R -2147483648

2147483647

Value of analog speed
input. See Pn300 and
Pn380.

BG Analog

Inputs

Analog_Torque 41

0.1 % of
max

R -2147483648

2147483647

Value of analog torque
input. See Pn400 and
Pn480.

BG Analog

Inputs

Application_gain 27

%

R/W

0

1000

Gain factor, multiplies the
value of Pn1A0.

C System

Profile

Clock 37

ms

R/W

0

2147483647

System clock

2

Status

Command_mode 26

R

1

2

Program mode: 1:
Program not running, 2:
Program running.

C Status

ECAM_Master_profile_
position

52 Counts

R -2147483648

2147483647

The current master
position in the ECAM
profile. It is a cyclic value
according to ECAM profile.
Valid only while ECAM is
engaged.

2 ECAM

ECAM_Master_scale_den 49

R/W 1

65535

The denominator of the
ECAM master scaling
factor. Changeable only
while not in ECAM mode.

C ECAM

ECAM_Master_scale_num 48

R/W 1

65535

The numerator of the
ECAM master scaling
factor. Changeable only
while not in ECAM mode.

C ECAM

ECAM_Offset 47

Position
Units

R/W -2147483648

2147483647

Specifies the required
offset along the slave axis
of the ECAM profile.

C ECAM

ECAM_Slave_profile_
Position

53

Position
Units

R -2147483648

2147483647

The current slave position
in the ECAM profile. It is a
cyclic value according to
ECAM profile. Valid only
while ECAM is engaged.

2 ECAM

ECAM_Slave_scale_den 51

R/W

1

65535

The denominator of the
ECAM slave-scaling
factor. Changeable only
while not in ECAM mode.

C ECAM

ECAM_Slave_scale_num 50

R/W

1

65535

The numerator of the
ECAM slave-scaling
factor. Changeable only
while not in ECAM mode.

C ECAM

ECAM_Shift 46

Counts

R/W

-2147483648

2147483647

Specifies the required shift
along the master axis of
the ECAM profile.

C ECAM

Electronic_gear_den 85

R/W

1 65536

Sets the electronic gear’s
denominator.

2 Status

Electronic_gear_num 84

R/W

1 65536

Sets the electronic gear’s
numerator.

2 Status

Exact_mode 25

R/W

0

1

Defines when a
commanded motion is to
be considered complete:
0: The theoretical motion
has ended, 1: The actual
position error is smaller
than specified by
Motion_end_window.

C Status