Home_sw_c – Yaskawa FSP Amplifier FlexWorks User Manual

Page 137

Advertising
background image

Command Reference

137

HOME_SW_C

G

ROUP

Home

S

YNTAX

HOME_SW_C <speed1> <speed2>

O

P

. C

ODE

130

M

ODES

Program, Sequential

D

ESCRIPTION

Finds the encoder C-pulse only after the home switch is

found. The motor moves at <speed1> to the home switch
and then changes direction and moves at <speed2>

towards the C-pulse. Only then does the encoder counter
zero and the motor decelerate to stop. The motor stops
after the C-pulse. Use the GO or GO_D command to set

the motor at the zero position.
<speed1> and <speed2> must have opposite signs, i.e.,

the movement is in opposite directions.
Note: When working with a linear motor and a Yaskawa
serial converter for the encoder, the maximum speed at
which the motor can move to the C-pulse is 5000 linear
scale pitch per second. For example, when the encoder
scale pitch is 20

μm, the maximum speed at which the

motor will move while executing a HOME_C command
will be 100mm/s.

speed1

The speed and direction of searching
for the home switch. Must have an
opposite sign to that of <speed2>.
[speed user units]

Serial

4 V

S

YNTAX

A

RGUMENTS

speed2

The speed and direction of searching
for the C-pulse. Must have an
opposite sign to that of <speed1>.
[speed user units]

Serial

4 V

S

EE

A

LSO

HOME_C, HOME_SW, HARD_HOME

R

ELATED

P

ARAMETERS

Pn2C7.0 Sets home switch input attribution.

Advertising
This manual is related to the following products: