List of Operation Codes
251
Example: 2 U V indicates that the argument consists of 2
hexadecimal digits, is unsigned, and can be specified either by
a numerical value or by a variable.
(3) Condition codes:
Sign Condition Setting
3a
3b
3c
3d
3e
==
Equal to
(Condition)
0
X
X
>
Greater than
1
X
X
<
Smaller
than
2
X X
>=
Greater than or
equal to
3
X
<=
Smaller than or
equal to
4
X
!=
Not equal to
5
X
*
Multiply
6
X
/
Divide
7
X
MOD Modulus
8
X
+
Plus
9
X
-
Minus
10 X
AND
AND
13 X
XOR
Exclusive
Or
14 X
OR
Or
15 X
=
Set equal to
18
X
(4) See the command description in Chapter 5, Command
Reference, for available options.
(5) Set to ID number of one of the system variables.