Serial Interface Protocol

202

Description: Message Identification (two bytes for two digits). Since
the range is greater than 0xF, two bytes are required for holding the
number. Message Identification is needed to bind a fault condition to
a specific command and to enable download (new or replace) of FSP

Amplifier program lines.

I

D

1

AND

I

D

2

Range: 0x0 – 0xFF. 0x0 – 0xF each

M

ESSAGE

I

DENTIFICATION

N

UMBER

D

ESCRIPTION

0x00

To ignore message identification

0x01 – 0xB4

Program line number (Program mode)

0xB5 – 0xC8

Message Identification (Immediate
and Sequential modes)

0xC9 – 0xFF

For future use

N

OTES

:

Message ID enables rewriting of lines in FSP Amplifier

program. The program must be stopped prior to line
rewriting.
Message ID enables synchronization between status
received from FSP Amplifier and a specific message

Message ID may be ignored and set as 0x00.

Description: Command Operational Code (two bytes for two digits).
Because the range is greater than 0xF, two bytes are required for

holding the number.

C1

AND

C2

Range: 0x0 – 0xFF. 0x0 – 0xF each (see Chapter 11, List of

Operation Codes).