Command Reference

121

FAST_OUTPUT_SETTING

G

ROUP

Output

S

YNTAX

FAST_OUTPUT_SETTING <Variable> <Condition>

<Value>

O

P

. C

ODE

154

M

ODES

Program, Immediate, Sequential

D

ESCRIPTION

This command is used to set an output to ON once the

specified <variable> has met a specified condition.

The output is set within 125 μs of the condition being
met. Using this command is more effective than using
an IF command followed by a SET_OUTPUT command,
which would result in the output being set only after

2 ms.
The output to be set to ON is specified in the
parameter Pn2D2.0, as explained below. Only one
output can be controlled by FAST_OUTPUT_SETTING.

S

YNTAX

A

RGUMENTS













Variable




The output can be conditional on any of
the following variables:

Variable Code

Position_demand_value 8

Position_actual_value 9

Following_error_actual_value 10

Torque_demand_value 17

Distance_from_target

*

36

Master_position 38

Absolute_position_error 61

*In general, this code is used for
In_position, but here it is used for

Distance_from_target.