Command Reference
155
Operation
Available operations:
Operator Code
* 6
/ 7
MOD 8
+ 9
- 10
AND 13
XOR 14
OR 15
Serial 1 U
S
YNTAX
A
RGUMENTS
(C
ONT
.)
Value
Long type.
Serial 4 V
E
XAMPLE
LABEL 1
SET_VAR Var_01 8192
MATH ECAM_Shift =
Actual_position_registration / Var_01
ECAM_ENGAGE 1 Non Cyclic
END
E
XAMPLE
E
XPLANATION
The ECAM_SHIFT variable is calculated by dividing the
Actual_position_registration by the value of Var_01.
For example, if Actual_position_registration is 19300,
ECAM_SHIFT will be set to 2, since 19300 / 8192 =
2.36 and only the integer part is considered.