Yaskawa FSP Amplifier FlexWorks User Manual

Page 181

Advertising
background image

Command Reference

181

Type

Specifies the rate of deceleration, and
whether the program is stopped.

Setting Code

Profile - The motor will

decelerate at the profile
acceleration (See section
12.2.2.).

0

Emergency – The motor will
decelerate at the quick stop
deceleration, specified by

parameters Pn2A8, Pn2A9.

1

Emergency + Program Stop
– The motor will decelerate

at the quick stop
deceleration, specified by

parameters Pn2A8, Pn2A9.
After stopping, the program

is terminated.

2

Serial

1 U

S

YNTAX

A

RGUMENTS

Servo

This argument defines the motor state
after the motion actually stops:

Setting Code

Servo ON - the motor
remains enabled.

0

Servo OFF - the motor is

disabled.

1

Serial

1 U

N

OTES

Unless <Type> is set to Emergency + Program Stop,

the program line following the STOP_EX command will
only be executed once the theoretical deceleration has
been completed.

Advertising