Parameters: ±2000 pulse (±5 mm)

1 pulse=2.5µm

The PH. MAIN menu

Use the PH. MAIN menu to maintain the cap and wiper and to clean the ink system (Refer to

How do I

maintain the printer?

).

Press the key to enter the service menu.

Ink system optimization (INK SYS OPT)

Use the INK SYS OPT option to select a service cleaning procedure.

Parameters:

STORE INK SYS — Use this parameter to clean the printheads and ink path with the maintenance
liquid while the ink system is primed with ink, and then recharge the maintenance liquid in the printer
to ensure long-term storage. Six maintenance liquid cartridges and six cartridges are mandatory.

CLEAN INK SYS — Use this parameter to clean the printhead with the cleaning liquid after long-term
storage. Six cleaning liquid cartridges and six priming cartridges are mandatory.

CAP CLEANING — Use this option to move the printhead carriage to the wiper position so that you
can clean the capping unit manually.

WIPER CLEANING — Use this option to lift the wiper blade so that you can clean the wiper blade
manually.

WASH PRINTHEADS — Use this option to fill the cap with ink to soak the printhead (nozzle surface)
in the ink for 1 to 2 hours to remove nozzle clogging.

CHARGE INK SYS — Use this parameter when priming the ink system.