Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 6

Configure and Start the Kinetix 5500 Drive System

Setup Screens

The setup screens provide the means of changing drive settings, for example, the
IP address. Press one of the SETUP buttons to access the setup screens.

You can use the soft menu items and navigation buttons to
view the information and make changes.

Press

to validate your changes:

If the change is invalid, the value doesn’t change.
If the change is valid, an asterisk appears next to the

changed attribute.

Table 52 - Navigating the Settings Menu

IMPORTANT

You must cycle control power to make network configuration changes
persistent. In this example, the IP address was changed. The change takes
affect and the asterisk disappears after control power is cycled.

Display configuration changes take effect immediately.

SETTINGS

DISPLAY

ESC

NETWORK

STATIC IP

SUBNET MASK

ESC

IP ADDRESS*

Settings Menu Selections

Sub Menu Selections

Attributes

Default

Description

Network

->Static IP

(1)

IP address

192.168.1.1

Indicates current IP address

Subnet mask

255.255.255.000

Indicates current subnet mask

Gateway

192.168.001.001

Indicates current gateway

DHCP

On

Turns DHCP on

Off

Turns DHCP off

Display

Backlight Timeout

30 sec…NEVER
(NEVER=no timeout period,
the backlight is always on)

-> 3 min

(1)

Sets backlight timeout period of the display

Contrast

-10…+10

0

Contrast setting of the display

Cyclic Data Select

(2)

->DC BUS

(1)

DC bus voltage

ENC TEMP

Encoder temperature in °C

INV UTIL

Inverter utilization in percent

INV TEMP

Inverter temperature in °C

CONV UTIL

Converter utilization in percent

CONV TEMP

Converter temperature in °C

SHUNT UTIL

Shunt utilization in percent

MOTOR UTIL

Motor utilization in percent

SPEED

RPM

OUT PWR

Output power in watts

OUT FREQ

Output frequency in hertz

OUT CUR

Output current in amps

(1) An arrow (->) appears in front of the chosen attribute indicating that this attribute is currently configured. This is also the factory default setting.
(2) The DC bus voltage is one of several cyclic data attributes. You can select any of the Cyclic Data Select attributes to be displayed on the Home screen.