Upgrade the Drive Firmware

Appendix B

Configure Logix5000 Controller Communication

This procedure assumes that your communication method to the Logix5000
controller is the Ethernet network. It also assumes that your Logix5000 Ethernet
module or controller has already been configured.

For more controller information, refer to

Additional Resources

on

page 12

.

Follow these steps to configure Logix5000 controller communication.

1. Open your RSLinx Classic software.
2. From the Communications menu, choose Configure Drivers.

The Configure Drivers dialog box appears.

3. From the Available Driver Types pull-down menu, choose Ethernet

devices.

4. Click Add New.

The Add New RSLinx Classic Driver dialog box appears.

5. Type the new driver name.

6. Click OK.

The Configure driver dialog box appears.