Apply the converter kit shield clamp – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 93

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

93

Connecting the Kinetix 5500 Drive System

Chapter 5

Apply the Converter Kit Shield Clamp

Follow these steps to apply the converter kit shield clamp.

1. Apply the shield clamp to the 12 mm (0.5 in.) of exposed cable shield to

achieve a high-frequency bond between the shield braid and clamp.

Apply 0.30 N•m (2.6 lb•in) torque to each screw.

2. Route and insert each wire to its assigned terminal.

Include a service loop, as shown in

Figure 54

, and refer to the connector

pinout in

Figure 53

.

3. Tighten each terminal screw.

Apply 0.22…0.25 N•m (1.9…2.2 lb•in) torque to each screw.

4. Gently pull on each wire to make sure it does not come out of its terminal;

reinsert and tighten any loose wires.

5. Attach the tie wrap for added stress relief.

IMPORTANT

Cable preparation and positioning that provides a high-frequency
bond between the shield braid and clamp is required to optimize
system performance.

Shield Clamp

Advertising